Montigo DHS Manual de usuario

Busca en linea o descarga Manual de usuario para Para Casa Montigo DHS. Montigo DHS User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 22
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
®
C US
Read and understand this manual. Improper installation, adjustment, alteration,
service or maintenance can cause serious injury, property damage or even death.
For assistance or additional information consult a qualified installer, service
agency or the gas supplier.
DANGER
Glass doors on gas fireplaces are extremely hot while the fireplace is on and
remain hot even after the fireplace has been turned off. Safety screens are
available and can reduce the risks of severe burns. Please keep children away
from the fireplace at all times.
CAUTION
Installation & Maintenance Manual
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of
this or any other gas burning appliance. A fire or explosion my occur causing serious
injury, property damage or even death.
WARNING
Installer: Leave this manual with the appliance. Do not remove.
Consumer: Retain this manual for maintenance and future reference. Do not Discard.
NOTICE
IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
DANGER
Irritant
Cutting
Watch your step
Slippery floor
High temperatures
Glass hazard
Danger of suffocation
High voltage
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Oxidising
Danger of death
Biohazard
Laser Radiation
Danger of entrapment
Hot surface
General Warning
Blank
Gas bottles
Watch for
falling objects
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
radiation
Radiation
Hazardous to the
Environment
Danger of harming
your hands
Irritant
Cutting
Watch your step
Slippery floor
High temperatures
Glass hazard
Danger of suffocation
High voltage
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Oxidising
Danger of death
Biohazard
Laser Radiation
Danger of entrapment
Hot surface
General Warning
Blank
Gas bottles
Watch for
falling objects
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
radiation
Radiation
Hazardous to the
Environment
Danger of harming
your hands
Irritant
Cutting
Watch your step
Slippery floor
High temperatures
Glass hazard
Danger of suffocation
High voltage
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Oxidising
Danger of death
Biohazard
Laser Radiation
Danger of entrapment
Hot surface
General Warning
Blank
Gas bottles
Watch for
falling objects
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
radiation
Radiation
Hazardous to the
Environment
Danger of harming
your hands
Irritant
Cutting
Watch your step
Slippery floor
High temperatures
Glass hazard
Danger of suffocation
High voltage
Flammable materials
Corrosive
Fork lift trucks
Danger overhead crane
Explosion risk
Oxidising
Danger of death
Biohazard
Laser Radiation
Danger of entrapment
Hot surface
General Warning
Blank
Gas bottles
Watch for
falling objects
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
XG0511 150203
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
DHS
Gas Fireplace
Insert
DHS
Gas Fireplace
Insert
Hotshot
Vista de pagina 0
1 2 3 4 5 6 ... 21 22

Indice de contenidos

Pagina 1 - XG0511 150203

®C USRead and understand this manual. Improper installation, adjustment, alteration, service or maintenance can cause serious injury, property damage

Pagina 2 - Table Of Contents

Page 10Hotshot Gas Fireplace InsertXG0511 - 150203InstallationStep 4. Install the Upper Louvre Assembly Position the Upper Louvre Assembly on top of

Pagina 3 - CAUTION NOTICE

Page 11Hotshot Gas Fireplace InsertXG0511 - 150203InstallationFigure 10a. Wiring diagram. Wiring for the Air Circulating Fan and ON/OFF SwitchThe Hot

Pagina 4

Page 12Hotshot Gas Fireplace InsertXG0511 - 150203InstallationFigure 11c. Installing the glass door.Do not use ammonia based or abrasive cleaners on

Pagina 5

Page 13Hotshot Gas Fireplace InsertXG0511 - 150203Installation2. Unpack the logs. Be sure to handle the logs carefully, as they are very fragile.3.

Pagina 6

Page 14Hotshot Gas Fireplace InsertXG0511 - 150203OperationTo Turn Off Gas To Appliance:3. Push in gas control knob slightly and turn clockwise

Pagina 7

P/N XG0511Page 15Hotshot Gas Fireplace InsertOperationOn/Off SwitchTheOn/OffSwitchislocatedonthetopright-handsideoftheHot-shotFireplace.

Pagina 8

Page 16Hotshot Gas Fireplace InsertXG0511 - 150203MaintenanceCAUTIONS Fireplacegascontrolmustbeinthe“OFF”positionandpilotand main burners

Pagina 9

Page 17Hotshot Gas Fireplace InsertXG0511 - 150203MaintenanceReplacing the Fans1.Turnoffgasandpowertothereplace.2. Remove the door and set

Pagina 10 - Installation

Page 18Hotshot Gas Fireplace InsertXG0511 - 150203MaintenanceTroubleshootingThe following is a troubleshooting chart of possible problems: PROBLEM

Pagina 11

Page 19Hotshot Gas Fireplace InsertXG0511 - 150203AppendixThe WarrantyTheCompanieswarrantstheDelRayGasAppliancetobefreefromdefectsinmater

Pagina 12

Page 2Hotshot Gas Fireplace InsertXG0511 - 150203Table Of ContentsIntroduction ...

Pagina 13

Page 20Hotshot Gas Fireplace InsertXG0511 - 150203AppendixAppendix: State of MassachusettsAmendment(Gas Fireplace / Equipment sold in the State of Mas

Pagina 14 - Operation

Page 21Hotshot Gas Fireplace InsertXG0511 - 150203Notes

Pagina 15

Ferndale, WashingtonTF: 1.800.789.6236FX: 1.866.3000.0927Langley, British ColumbiaTF: 1.800.378.3115FX: 1.604.607.6462XG0511 - 150203Gas FireplaceInse

Pagina 16 - Maintenance

Page 3Hotshot Gas Fireplace InsertXG0511 - 150203InstallationSafety Key AlertIntroductionIndicates a hazardous situation which, if not avoided, WILL r

Pagina 17

Page 4Hotshot Gas Fireplace InsertXG0511 - 150203InstallationIMPORTANT MESSAGE: SAVE THESE INSTRUCTIONSThe Hotshot fireplace insert must be installed i

Pagina 18 - Replacement Parts

Page 5Hotshot Gas Fireplace InsertXG0511 - 150203InstallationRating Plate Sample 

Pagina 19 - Appendix

Page 6Hotshot Gas Fireplace InsertXG0511 - 150203InstallationFigure 1. Fireplace dimensions. (Tolerance ⅛")39¾”27¾”26”39¾”Unit DimensionsA BWSFB

Pagina 20 - Amendment

Page 7Hotshot Gas Fireplace InsertXG0511 - 150203InstallationInstalling The Gas LineThegaslinemustbeinstalledbeforenishingtheHotshotDHSins

Pagina 21 - Hotshot Gas Fireplace Insert

Page 8Hotshot Gas Fireplace InsertXG0511 - 150203InstallationChimney Liner InstallationThis appliance is for installation with 4" diameter Type-B

Pagina 22 - Gas Fireplace

Page 9Hotshot Gas Fireplace InsertXG0511 - 150203InstallationInstalling the Face Plate, Trim, and LouvresBefore you Begin: Wear gloves while installin

Comentarios a estos manuales

Sin comentarios