Montigo L52DF-ST El manual del propietario

Busca en linea o descarga El manual del propietario para Chimeneas Montigo L52DF-ST. Montigo L52DF-ST Owner`s manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
www.montigo.com
XG0811 Canadian Heating Products Inc. Langley, BC V4W 4A Montigo Del Ray Corp. Ferndale, WA 98248 081009
L52DF-ST
Indoor
Installation Operation & Maintenance Manual
Check local codes and read all instructions prior to installation.
L52DF-ST Gas Fireplace
f i r e f e a t u r e
L52DF-ST Indoor Shown
For Your Safety:
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
Safety Notice:
Glass doors on gas fireplaces are extremely hot while the fireplace is on and remain
hot even after the fireplace has been turned off. Safety screens are available and
can reduce the risks of severe burns.
®
C US
Warning:
Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to this manual. For assistance or additional
information consult a qualied installer, service agency or the gas supplier.
Warning:
What to do if you smell gas
Do not try to light any appliance.
Do not touch any electrical
switch; do not use any phone in
your building.
Immediately call your gas
supplier from a neighbor's
phone. Follow the gas supplier's
instructions.
If you cannot reach your gas
supplier, call the re department.
Installer: Leave this manual
with the appliance.
Consumer: Leave this
manual for future reference.
Vista de pagina 0
1 2 3 4 5 6 ... 23 24

Indice de contenidos

Pagina 1 - L52DF-ST Gas Fireplace

www.montigo.comXG0811 Canadian Heating Products Inc. Langley, BC V4W 4A Montigo Del Ray Corp. Ferndale, WA 98248

Pagina 2 - Table Of Contents

Page 10L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e InstallationWiringGas Control and Pilot WiringL52DF-ST-IFigure 26. W

Pagina 3 - Introduction

Page 11L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e InstallationTo install the door, hook the top edge of the door frame

Pagina 4

Page 12L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e Operation - Model L52DF-STL52DF-STWARNING: If you do not follow thes

Pagina 5

Page 13L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e Operation - Model L52DF-ST-I L52DF-ST-IFor Your Safety - READ BEFORE

Pagina 6

Page 14L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e B-Series BF-AL-Series DF-IOperation

Pagina 7

Page 15L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e MaintenanceGeneral Q Have the replace and installation inspected yea

Pagina 8

Page 16L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e MaintenanceGas Control Valve Troubleshooting L-52-DF-IManifold Pressu

Pagina 9

Page 17L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e MaintenanceSpare Parts - L52DF(O)-STNG Gas Valve RGC1006LP Gas Valve

Pagina 10 - Installation

Page 18L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e The WarrantyThe Companies warrants the Montigo Gas Appliance to be fr

Pagina 11

Page 19L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e Appendix A - Termination LocationsA = clearance to the termination f

Pagina 12 - Operation - Model L52DF-ST

Page 2L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e CongratulationsCongratulations on selecting a FireFeature gas replace

Pagina 13 - Gas Control Switch

Page 20L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e Amendment (Gas Fi

Pagina 14 - Operation

Page 21L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e Notes

Pagina 15 - Maintenance

Page 22L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e Notes

Pagina 16

Page 23L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e Notes

Pagina 17

Canadian Heating Products Inc.Langley, BC V4W 4A1Montigo Del Ray Corp.Ferndale, WA 98248XG0811(O) - 042009

Pagina 18 - Warranty

Page 3L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e IntroductionThank You for choosing a Montigo Gas Fireplace.About this

Pagina 19 - Part No. XG0711

Page 4L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e InstallationInstalling The Fireplace ShellThereplacemaybeinstalle

Pagina 20

Page 5L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e InstallationInstalling The Gas LineThegaslinemustbeinstalledbefo

Pagina 21

Page 6L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e InstallationInstalling Terminations with Built-In FramesInstalling Ter

Pagina 22

Page 7L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e 120ABCInstallationTop Vent Venting RunsL52DF-STExample A: (Unacceptabl

Pagina 23

Page 8L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e InstallationFigure 15. Straight, vertical venting showing required PX

Pagina 24 - Montigo Del Ray Corp

Page 9L52DF(O)-ST See-thru Gas FireplacePart No. XG0711f i r e f e a t u r e InstallationFinishing Around the FireplaceCombustible mantels and moul

Comentarios a estos manuales

Sin comentarios