Installation
Operation &
Maintenance
Direct-Vented
Gas Fireplace
M38DV-PRC
Panorama
Warning:
Improper installation, adjustment,
alteration, service or maintenance can
cause injury or property damage. Refer to
this manual. For assistance or additional
information consult a qualied installer,
service agency or the gas supplier.
What To Do If You Smell Gas:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier, call the re department.
For Your Safety:
Do not store or use
gasoline or other ammable
vapors and liquids in the
vicinity of this or any other
appliance.
®
C US
Installer: Leave this manual
with the appliance.
Consumer: Leave this man-
ual for future reference.
Check local codes and read all
instructions prior to installation.
Safety Notice:
Glass doors on gas replaces are
extremely hot while the replaces is on
and remain hot even after the replace
has been turned off. Safety screens
are available and can reduce the risks
of severe burns. Please keep children
away from the replace at all times.
Vista de pagina 0
1 2 3 4 5 6 ... 21 22

Indice de contenidos

Pagina 1 - Panorama

InstallationOperation &MaintenanceDirect-VentedGas FireplaceM38DV-PRCPanoramaWarning:Improper installation, adjustment, alteration, service or

Pagina 2 - Table Of Contents

XG0204 04/05Page 10Panorama Direct Vented FireplaceInstallationOperationLighting InstructionsSee Pages 11-12. Figure 15. Log Installation.Installing

Pagina 3 - Installation

Page 11XG0204 04/05Panorama Direct Vented FireplaceFor Your Safety - READ BEFORE LIGHTING:WARNING: If you do not follow these instructions exactly,

Pagina 4

XG0204 04/05Page 12Panorama Direct Vented Fireplace What To Do If You Smell Gas: Do not try to light any appliance. Do not touch any electrical

Pagina 5

Page 13XG0204 04/05Panorama Direct Vented FireplaceFor Your Safety - READ BEFORE LIGHTING:To Turn Off Gas To Appliance:Lighting Instructions:WARNING

Pagina 6

XG0204 04/05Page 14Panorama Direct Vented FireplaceMaintenanceGeneral Have the fireplace installation inspected yearly, including a visual check of

Pagina 7

Page 15XG0204 04/05Panorama Direct Vented FireplaceMaintenanceTroubleshooting If your fireplace still does not operate correctly, consult your dealer

Pagina 8

XG0204 04/05Page 16Panorama Direct Vented FireplaceWarrantyThe WarrantyThe Companies warrants the Montigo Gas Appliance to be free from defects in ma

Pagina 9

Page 17XG0204 04/05Panorama Direct Vented FireplaceAppendix A - Termination LocationsA = clearance to the termination frame above grade, veranda, po

Pagina 10 - L og ‘ D’

XG0204 04/05Page 18Panorama Direct Vented FireplaceAppendix B - Spare Parts & AccessoriesNote: Use only original replacement parts. This will pro

Pagina 11 - Gas Control Knob

Page 19XG0204 04/05Panorama Direct Vented FireplaceNotes

Pagina 12 - Operation - Model M38DV-PRC

XG0204 04/05Page 2Panorama Direct Vented FireplaceIntroductionThe 38 Series Direct Vent - Panorama is a multi-sided Gas Fireplace with an adjustable

Pagina 13 - Gas Contr ol Switch

XG0204 04/05Page 20Panorama Direct Vented FireplaceNotes

Pagina 14 - Maintenance

XG0204 04/05Page 21Panorama Direct Vented FireplaceNotes

Pagina 15

Canadian Heating Products Inc.Langley, BC V4W 4A1Montigo Del Ray Corp.Ferndale, WA 98248XG0204 - 011707

Pagina 16 - Warranty

Page 3XG0204 04/05Panorama Direct Vented FireplaceInstallationInstalling The Fireplace ShellThe fireplace may be installed in any location that mainta

Pagina 17 - XG0204 04/05

XG0204 04/05Page 4Panorama Direct Vented FireplaceInstalling The Gas LineThe gas line must be installed before finishing the M38DV-PRC fire-place. Natu

Pagina 18

Page 5XG0204 04/05Panorama Direct Vented FireplaceInstallationInstalling Heat Guards over Terminations 1. Ensure that the two long mounting brackets

Pagina 19

XG0204 04/05Page 6Panorama Direct Vented FireplaceInstallationHorizontal Vent InstallationVent systems that terminate through a wall may comprise up

Pagina 20

Page 7XG0204 04/05Panorama Direct Vented FireplaceInstallationVertical Vent InstallationsVertical Terminations must be installed: • minimum 2&ap

Pagina 21

XG0204 04/05Page 8Panorama Direct Vented FireplaceFinishing Around the FireplaceCombustible mantels and mouldings may be safely installed over the to

Pagina 22 - XG0204 - 011707

Page 9XG0204 04/05Panorama Direct Vented FireplaceInstallationWiringFigure 15b. Fan wiring schematic.Gas Control and Pilot WiringHoneywell (Q3450)Pil