EDVRSPV Vertical Power Vent System
Part No. XG1302 - 120110
f i r e f e a t u r e
Installation
Figure 1. Typical Venting Installations.
Venting Installation
It is recommended that the External Power Vent System be used with
a gas replace that is equipped with HSI. When installing the vent-
ing, the installation must adhere to the Vent Installation Section in the
replace's Installation Operation and Maintenance Instructions, as well
as the following guidelines:
■Ensure that the planned termination location is acceptable as
shown in Appendix A.
Maximum allowed vent run is 100 feet.
Figure 2. Multi-elbow Venting Installations.
Multi-Elbow Installations
Multi-elbow installations are possible up to a maximum of six 90°
elbows.
V
Restrictor #1
Max V Max Elbows
100’ feet six 90
Elbow 1
Elbow 2
Elbow 3
Elbow 5
Elbow 4
H2
H1
V1
V2
V3
Restrictor #1
Max V1 + H1 + V2 + H2 + V3 + H3 Max Elbows
100’ feet six 90
Installing the Power Vent
Figure 4.
Step 1.
Construct a chase box around the vent penetration with exterior
dimensions of 17"x 17" x 16"MIN in height.
17”
17”
18”
Figure 3. Downward Venting Installations.
Downward Vertical Venting (HSI Models Only)
Downward venting installations are only possible with gas replaces
equipped with Electronic or Hot Surface Ignition (HSI).
Restrictor #1
Max V1 + H1 + D + H2 + V3 Max Elbows
100’ feet six 90
Elbow 1
Elbow 2
Elbow 3
Elbow 5
H1
V1
D = 6’ foot
MAX
V3
H2
Elbow 4
Page 5