H*38DF-CLCR Corner Gas Fireplace
Installation
MODEL
Top -
Rear Vent
Top -
Top Vent
Header
Side
(Solid side)
Floor
Back
Venting - Top
Venting - Sides,
bottom
Mantle
H*38C* 13" 17 1/2" 4" 5" 0" 1" 2" 1" **
Clearances
When installing a shelf over the top of the replaces, the following
guidelines must be adhered to:
For Rear Vent applications, the minimum clearance is 1" from the rear of
the replace to a wall, or any combustible materials, and 13" clearance
from the top of the replace to the underside of any combustible shelf
materials.
For Top Vent applications, the minimum clearance is 1" from the rear
of the replace to a wall, or any combustible materials, and 17 1/2" to
the underside of any combustible shelf materials.
1” clearance is maintained on sides and bottom of vent runs and 2”
above horizontal vent runs to any combustible material.
Installing The Standoffs
To avoid elevated mantel temperatures, all H*38C* gas replaces
are required to have the supplied standoffs installed. The replace is
supplied with two standoffs. Bend and install these standoffs on top
of the replace as shown in Figure 6, ensuring that the height of the
standoff maintains a 4" clearance from the top of the unit to the 1st
combustible stud.
Nailing Flange Extension
The 4" nailing ange extension is shipped attached to the top edge of
the replace, see Figure 1.
The nailing ange extension may be substituted with a piece of NON-
Combustible material of the same thermal characteristics, ie: cement
board or equivalent to t the opening. This is recommended in applications
where the facing materials will not adhere to the metal nailing ange.
To remove the Nailing Flange Extension follow the directions below:
Figure 6� Installing the H*38C* standoffs.
Note: Clearance from top of replace to a ceiling within the replace
enclosure.
** Note: For mantel clearance, please refer to Section 6: Finishing
on page 21.
Figure 7c� Finished removing Nailing Flange extension.
Figure 7� Remove screws from top of the unit
Figure 7a� Remove shell and insulation from the top of unit. Remove screws
from outer edge.
Figure 7b� Remove the nailing ange extension from the unit. Reinstall shell
and insulation. Screw shell in place.
4”