OFF command troubleshooting fl ow chart
OFF
command
Main burner
turns OFF?
NO
1. Verifiy transmitter-receiver communication
2. Remove the electrical wire connector from the EV1 (green base)
and EV2 (red base) on the gas valve. If the main burner still
remains lit continuously, turn off the gas supply to the appliance,
and replace the gas valve.
Pilot turns
OFF?
YES
YES
END
NO
1. Verify the status of the IPI/CPI switch. If the IPI/CPI switch is in
CPI position the system behaves as expected.Otherwise, check
with manufacturer's instruction manual.
2. Remove the electrical wire connector from the EV1 (green base)
on the gas valve. If the pilot still remains lit continuously, turn off
the gas supply to the appliance, and replace the gas valve.