6 Additional troubleshooting information
6.1 DFC power supply verifi cation
Battery supply test
Switch off the FCM if present. Measure voltage between CN1.1 (+) and CN1.3 (-) at the DFC
board (see wiring diagram in the DFC installation manual).
The measured voltage should be between 4.4Vdc and 6.4Vdc. Less than 4.4Vdc could indicate
drained batteries. To be also sure, each single battery level should be measured greater than
1.1Vdc.
6.2 AC/DC supply test
Turn FCM ON or plug in the AC/DC adapter. Measure voltage between CN1.2 (+) and CN1.3 (-)
at the DFC board (see wiring diagram in the DFC installation manual).
The measured voltage should be between 6.7Vdc and 7.3 Vdc for the AC/DC adapter.
The measured voltage should be between 6Vdc and 6.4 Vdc for the FCM.
7 Available documentation
CODE DESCRIPTION LANGUAGE
9957018 880 PROFLAME Use and Installation Instructions GB
9957039 885 PROFLAME Use and Installation Instructions GB
9957063 886 PROFLAME Use and Installation Instructions GB
9957061 PROFLAME DFC Use and Installation Instructions GB
9957015 GT System Use and Installation Instructions FR
9957016 GTM System Use and Installation Instructions FR
9957017 GTMF System Use and Installation Instructions FR
9957028 Prolame GTMF System Use and Instructions FR GB
9957029 Profl ame System with the SPLIT FLOW feature GB
9957030 584 Profl ame GTMF Transmitter GB
9957031 584 Profl ame GTMF Receiver GB
9957032 584 Profl ame GTMF Fan Control Module GB
9957035 584 Profl ame GTMF System GB
9957036 584 Profl ame GTM System GB
9957037 584 Profl ame GT System GB
9957038 584 Profl ame Receiver (S) GB
9957014 Split fl ow Use and Installation Instructions GB
9957100 Pilot Burner Use and Installation Instructions GB
7252627 PROFLAME HI/LO conversion kit GB
7252628 PROFLAME Stepper motor conversion kit GB
7252638 Assembly instructions (LPG) GB
7252639 Assembly instructions (NG) GB
Comentarios a estos manuales