Page 11
L-Series DF-ST See-thru Gas Fireplace
Part No. XG0812
f i r e f e a t u r e
Installation
Figure 18. Reducing Vertical Vent from 5/8" to 4/7".
Reduced Vertical Installation
It is possible to reduce vertical vent runs from 5"/8" venting to 4"/7"
venting. Reduced vertical venting may only be used when the installation
exceeds 12 feet and terminates through the roof, and if the vertical vent
reducer is used with the following venting conguration.
Finishing Around the Fireplace
Combustible mantels and mouldings may be safely installed over the
top and on the front of the replace provided that they do not project
beyond shaded area shown in Figure 24. Side wall clearances are 3".
Combustible surrounds may be installed with 3" clearance to the side
of the replace as shown in Figure 25.
Fireplace Facing
When selecting the nish material for your replace, it is important to
remember the following: THE HORIZONTAL LOUVRES MUST NOT
BE OBSTRUCTED IN ANY WAY - to do so restricts the air supply
for the control compartments and heat exchanger it also prevents
access for servicing controls.
The face of the replace may be painted to match the room decor,
provided you use a heat-resistant paint. Decorative facing must not
extend past the replace opening at all, because it will interfere with
the access to retainers for removal of glass door.
Figure 24. Combustible mantles and facings.
Horizontal Run (in)
Non-Combustible
Facing Material
N
on-Combustible
F
acing Material
Non-combustible Header
(Supplied by Montigo)
Drywa
ll
/ S
h
eetroc
k
6”
6”
3
Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements
are for re hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
replaces which are hot, fuel and energy efcient.
Please be aware; temperatures over the mantel will rise above normal
room temperature and walls above replace may be hot to touch.
Warning:
When covering the upper metal portion of the replace with a non-
combustible material Please Note: The decorative facing materials
may be subject to temperatures in excess of 250° F. This should be
considered when selecting facing materials.
We recommend careful consideration be given to the effects of elevated
mantel temperatures which may be in excess of product design, for
example: candles, plastic or pictures. This can cause melting, deformation,
discoloration or premature failure of T.V. and radio components.
Painting:
Special care is recommended by the Master Painters and Decorators
Association, when painting the replace surrounds, to select and apply
a quality Alkyd sealer prior to the applying of latex paints. This is to
prevent leaching of water from evaporation and causing a brownish
staining effect to paint over coats.
Figure 25. Combustible surrounds, (Both Sides Typical).