L-Series DF-ST See-thru Gas Fireplace
Part No. XG0812
f i r e f e a t u r e
Installation
Installing The Fireplace Shell
The replace may be installed in any location that maintains proper clear-
ances to air conditioning ducts, electrical wiring and plumbing. Safety,
as well as efciency of operation, must be considered when selecting
the replace location. Try to select a location that does not interfere
with room trafc, has adequate ventilation, and offers an accessible
pathway for Direct Vent installation. Refer to page 4 - Vent Installation
for more information.
The replace dimensions are shown below:
When installing a shelf over the top of the fireplace, the
following guidelines must be adhered to: For Rear Vent
applications the minimum clearance from the top of the replace
to a shelf is 10" (L38) and 12" (L42). For Top Vent applications, the
minimum clearance are shown in the clearance table. (Minimum
2" clearance must still be maintained around the vent pipes.)
Figure 2. Framing dimensions.
Framing
WARNING:
When this appliance is installed directly on carpeting, tile or
any combustible material other than wood ooring, it must be
installed on a metal or wood panel extending the full width and
depth of the appliance.
Top View
Front View
Side View
Clearances
These clearances apply to all dimensions except the framed opening,
where the clearance to combustibles is 0". The L38DF-ST and L42DF-ST
clearance to unprotected combustible walls which are perpendicular to
the replace opening, must not project beyond the shaded area shown
in Fig. 24.
For protection against freezing temperatures, it is recommended that
outer walls of the chase be insulated with a vapor barrier. This will reduce
the possibility of a cold-air convection current on the replace.
Figure 1. Fireplace dimensions.
* Clearance from the top of the
to a combustible ceiling within the
enclosure.
** Refer to page 14.
5 1/2”
5 1/4”
E
B
L
A B C D E F G H I J K L
L38DF-ST
37
3
/
4 29
1
/
2 36
1
/
2 1
1
/
4 17
1
/
2
24
36
3
/
8 7 5 8 34
L42DF-ST
41
7
/
8 30
1
/
2
39
1
/
2
1
1
/
4
18
1
/
2 24 40
1
/
2 34
1
/
2
7 5 8
1
1
17 1/2"
Sides
1"
Floor
0"
Mantle
4"
Top (Top Vent )
L38DF-ST
L42DF-ST
10"
Top (Rear Vent)
Back
3”
Annulus
2"
17 1/2"
2"
0"
4"
12"
3”
2"
Notes:
Install supplied metal header
above fireplace after unit is in
place. Use supplied hardware to
fasten to framing.
Both sides Typical. Unit may not
be exactly as shown.
N
O
M
P
M
O
L38DF-ST
40
37
23
3
/
4
N
Framing Dimensions
3
/
4
L42DF-ST
40 42
23
3
/
4
P
34
1
/
2
35
1
/
2
Vista de pagina 2