Page 9
L-Series DF-ST See-thru Gas Fireplace
Part No. XG0812
Figure 14. Short horizontal installation.
Heat Shields
Due to high ue temperatures, the heat shield (RHS101) must be
used on all installations straight through the wall, at the point
where the vent pipe connects to the termination. With the heat shield,
vent clearances can be maintained at 1". The heat shield is not
included with the replace.
Example:
A 10' section of rigid pipe and a 90° elbow may be used in conjunc-
tion with a 3 ft. flex section (PFL-3) will, when extended in a chase,
allow for a maximum horizontal run of twelve and one-half feet from
the centre of the fireplace to outside wall and a minimum of 7'6" when
retracted in opposite direction. (See Figure 9.)
Long Vent Runs:
For longer or more complex vent runs, vertical lift is required. First
ensure that the planned run is acceptable using the Vent Graph. Plan
out the required components using the chart above. You may be able
to use fewer components using the chart below.
Figure 16. Extended horizontal installation using a combina-
tion of rigid and flex venting.
Figure 15. Heat Shield for short horizontal installation. Install
by sliding over the vent pipe where it connects to
To install the heat shield, slide one section over the vent pipe on the
inside of the wall opening, with the circular portion inside the wall
cavity. Screw the shield in place over the wall opening. Install the
second section on the outside of the wall opening sliding the circular
portion into the wall opening. Refer to Figure 8.
33
"D" flex sections and "E" solid sections may be used in conjunction
with one another to obtain different possible horizontal length instal-
lations. NOTE: Flex section must not exceed maximum horizontal
length of 3 feet, and for this application the top clearance is to the
ceiling.
Installation
RHS8