Page 7
L-Series DF-ST See-thru Gas Fireplace
Part No. XG0812
Installation
Note: Flame characteristics will change if the maximum vent height
is used.
Minimum clearances 2" from vent to all combustible materials must
be maintained.
A maximum of two offsets (each offset has two 90° bends) may be
made and shall not exceed total length of 25% of the vertical vent
height, when measured center to center of piping.
Example: Typical vent installation.
20' vertical vent
2 - 2' offsets required
25% of 20' = 5' max. offset allowed
This venting configuration meets requirements.
4" / 7" Venting 5" / 8" Venting
A - Termination MVTK-1 PVTK-1
B - Flex Sections MFL-1 (12" Section)
MFL-2 (24" Section)
MFL-3 (36" Section)
MFL-4 (48" Section)
PFL-1 (12" Section)
PFL-2 (24" Section)
PFL-3 (36" Section)
PFL-4 (48" Section)
C - Rigid Sections MEXT-1 (12" m/f Section)
MEXT-2 (24" m/f Section)
MEXT-3 (36" m/f Section)
MEXT-4 (48" m/f Section)
PEXT-1 (12" m/f Section)
PEXT-2 (24" m/f Section)
PEXT-3 (36" m/f Section)
PEXT-4 (48" m/f Section)
D - Support Ring
& Plate
MSPXT-8 PSPXT-8
E - Firestop FS-8 PS-8
F - Roof Flashing MRF-7 (1/12 - 7/12 pt.)
MRF-12 (7/12 - 12/12 pt.)
PRF-7 (1/12 - 7/12 pt.)
PRF-7 (7/12 - 12/12 pt.)
G - Adaptor / Vent
Reducer
PVA5487 (5"/8" to 4"/7")
Figure 10. Straight, vertical venting showing required PXT-10 adaptor
(supplied with the PVTK-1 termination).
MEXT/PEXT
MEXT/PEXT
MXT-10/PXT-10
* For venting MIN 1" clearance to all vertical combustibles,
MIN 2" to all horizontal combustibles.
Figure 11. Vertical venting with 1 offset (1 offset= two 90° bends).
Figure 12. Vertical venting with 2 offsets (1 offset= two 90° bends).
* For venting with four 90° a restrictor may need to be used. (PEXT
5/8 Vent).